Best Pacific Hai Duong Solar Monitoring System & Control Panel
-
Client
Best Pacific Hai Duong Factory
-
Scope of Work
SCADA System & Master Control Panel
-
Industry
Rooftop Solar
Key features
-
Zero Export & Hybrid Control
Ensures solar power generation closely tracks load demand without feeding excess power back into the national grid. The Hybrid mode enables safe parallel operation with generators, optimizing fuel efficiency and protecting generator equipment.
-
Real-Time Monitoring & Control
Delivers real-time tracking of yield, power output, current, and voltage. Supports a manual mode for direct control of inverter switching and Air Circuit Breaker (ACB) operation straight from the HMI screen.
-
Data Acquisition & Intelligent Alarm Management
RTU panels continuously acquire data from inverters, weather stations, and energy meters. The system automatically triggers fault alarms complete with detailed root-cause analysis and troubleshooting guidance directly on the software interface.
Supply and installation of a rooftop solar SCADA system integrated with Zero Export features and safe hybrid operation alongside diesel generators for the Best Pacific Hai Duong factory.
Standard Specifications
Solution Detail & Operating Principle
Project Overview
Hino Systech Vietnam successfully executed the installation of a rooftop solar SCADA monitoring and control system at the Best Pacific Hai Duong plant. The solution provides the client with a comprehensive platform to closely monitor operational processes while maximizing the solar energy yield.
System Architecture
The system is designed with an integrated architecture featuring a Master Control Panel that handles complex control algorithms (such as Zero Export and Hybrid control) alongside a network of distributed RTU panels. These RTUs act as intermediate data stations, continuously collecting accurate operational metrics from field inverters, weather stations, and energy meters.
Core Operational Features
-
Real-Time Monitoring: Operators can monitor detailed yield, power output, current, and voltage for each individual inverter as well as the overall system.
-
Direct Control via HMI: Manual mode allows operators to quickly execute inverter start/stop sequences and trip/close Air Circuit Breakers (ACBs) directly from the screen interface.
-
Hybrid & Zero Export Solution: The system automatically regulates solar power generation to match the factory's real-time power consumption, ensuring zero reverse power flow to the national grid. Furthermore, it operates safely in parallel with backup generators, generating significant fuel savings for the plant.
-
Rapid Incident Response: Featuring an intuitive, user-friendly software interface, the system not only flags faults upon detecting anomalies but also provides clear root causes and step-by-step troubleshooting actions for each specific error code.
Why Hino Systech Is the Preferred Choice
The project at Best Pacific Hai Duong reaffirms Hino Systech's position, leveraging dynamic expertise combined with deep industry heritage:
-
Adhering to rigorous Japanese working methodologies and technology standards.
-
Backed by a highly qualified engineering team inheriting over 50 years of experience in industrial automation systems.
-
Committed to delivering high-quality solutions at competitive investment costs, maximizing economic returns for project investors.
Supply and installation of a rooftop solar SCADA system integrated with Zero Export features and safe hybrid operation alongside diesel generators for the Best Pacific Hai Duong factory.
Get a Power-Quality Survey & Switchboard Design Quote
Optimize your plant's energy costs today with a smart power-factor correction system. Hino Systech's expert engineers will run an on-site measurement survey and propose the optimal technical plan — completely free.
- Head office: Unit 1 & 2, 13th Floor, PV Oil Building, 148 Hoang Quoc Viet Street, Nghia Do Ward, Hanoi City
- Project support: hsv-sales@hino-systech.com
Related projects
-
Deployment of Solar Monitoring System for Net Zero Wooden House Model
Operation and periodic maintenance for 50MW solar power plants — 24/7 remote technical support, ensuring stable power generation performance.
Read more -
Rooftop Solar SCADA System at Sapporo Long An Plant
Upgrading line-wide control and monitoring systems for Japanese FDI clients.
Read more -
Hino – Wistron
PLC/HMI programming, robotics integration, and inspection cameras — standardizing operational workflows.
Read more